The following types of data files are saved in the Data window:
• Calibration History Files
A calibration history file is saved for each instrument that has
been downloaded. It records the calibration information for
every calibration that was downloaded. The GX-2003 can
save information for up to 20 calibrations in its memory.
• Interval Trend Data Files
Interval trend data is logged at the interval time defined in the
GX-2003. Each logged point is an average reading over the
previous time interval.
• Alarm Trend Data Files
Alarm trend data is logged around an alarm event. The GX-
2003 can save up to 8 alarm trend data files in its memory.
• Alarm Event Files
Alarm event files record gas alarm events that have been
downloaded from instruments. The GX-2003 can save up to
100 alarm events in its memory.
•Trouble Event Files
Trouble event files record sensor failure and system failure
events that have been downloaded from instruments. The