13 Operation Model GP-01 Operator’s Manual
Alarms
This section covers alarm indications. It also tells you how to reset the
Model GP-01 after an alarm has occurred and how to respond to an alarm
condition.
Alarm Indications
The Model GP-01 will sound an alarm, flash its alarm lights, and vibrate
when the target gas concentration rises above the low alarm point. The
Model GP-01 also sounds an alarm, flashes its alarm lights, and vibrates
when the high alarm point is reached. In addition, the Model GP-01 has a
low battery warning, a dead battery alarm, an over range alarm, a sensor
failure alarm, and a system failure alarm. See Table 4 below for a
description of each alarm indication.
Table 4: Alarm Types and Indications
Alarm Type LCD Indications Other Indications
Low Alarm
Concentration of gas
rises above the low
alarm point.
Gas reading
flashes.
Back light turns on.
Pulsing tone occurs
once per second.
Unit vibrates once
per second.
Alarm lights flash
once per second.
High Alarm
Concentration of gas
rises above the high
alarm point.
Gas reading
flashes.
Back light turns on.
Pulsing tone occurs
twice per second.
Unit vibrates twice
per second.
Alarm light flashes
twice per second.
Over Range
Concentration of gas
rises above the
measuring limit of the
Model GP-01. (Or
there could be a
problem with the unit.)
Gas reading
replaced by blinking
brackets.
Back light turns on.
Pulsing tone occurs
once per second.
Unit vibrates once
per second.
Alarm light flashes.
Low Battery Warning Last remaining bar
on the right in
battery icon
flashes.
•None