User Manual

Model GP-01 O
p
erator’s Manual Maintenance • 3 1
3. Rotate the membrane retainer about one-quarter turn counterclockwise
to remove it from the sensor retainer (the top of the unit).
4. Carefully remove the old lter or lters from the recess in the senor
retainer.
NOTE: Install the new sensor lter or lters into the recess. If H
2
S
scrubber lters are used, put them in rst. Make sure they are
properly seated in the recess. Then insert one sensor cover in the
recess over the two H
2
S scrubber disks.The H2S scrubber lters
are shown for reference in case they are installed. They are not
installed as shipped from the factory. See “Combustible Gas
Detection” on page 15 for a discussion of when they should be
installed.
CAUTION: If the H
2
S scrubber disks are installed, be very careful not to
push them too far into the recess in the sensor retainer. Lay
the disks carefully in the opening on top of the small tabs in the
recess.
5. Reinstall the membrane retainer.
Figure 12: Replacing the Sensor Filters