4-3. External output operation
Specifications 4 - 20 mA Power-line communication system (NT)
Signal Transmission System Electric current transmission (non-isolated) 2-wire type DC power-line communication
system
Transmission Path CVVS KPEV-S
Transmission Distance Below 1 km Below 300 m (depending on the system
designing conditions)
Connection Load Resistance Below 300 -
c
Detection Mode (No Alarm) 4 - 20 mA (concentration output) Concentration data
d
Detection Mode (Gas Alarm) 4 - 20 mA (concentration output) Concentration data, Alarm bits
e
Initial Clear
Depending on the setting of f
2.5 mA setting: 2.5 mA
4 mA, HOLD, 4-20 mA setting: 4 mA*
Initial bit
f
Maintenance Mode 2.5 mA setting: 2.5 mA
4 mA setting
: 4mA*
HOLD Setting: the previous value retained
4-20 mA setting
: 4 - 20 mA (concentration output)
Concentration data, Adjustment bit
g
Alarm Test Output ON setting: 4 - 20 mA (concentration output)
Output OFF setting: In accordance with setting of f
Concentration data, Adjustment bit, Test bit
h
Fault Alarm 0.5 mA (Fixed) Fault bits
i
Inhibit
Depending on the setting of f
2.5 mA setting: 2.5 mA
4 mA, HOLD, 4 - 20 mA setting: 4 mA*
Concentration data, Adjustment bit, Inhibit bit
j
Power Off 0 mA Signal OFF
* OSU - 0 - 25 vol% is equivalent of AIR (20.9 vol% = 17.4 mA)