Manual

65-2451RK-04 Hydrogen Transmitter • 7
Figure 3: Wiring the Detector to the Amplifier
10. Reinstall the detector terminal strip into its socket.
11. If shielded cable is used, connect the cable’s drain wire to an available chassis (earth)
ground at the amplifier junction box. The amplifier mounting screw is a convenient
grounding location. Install a lug on the shield drain wire or wrap the shield drain wire
around the mounting screw. Do not connect the shield drain wire at the detector
junction box.
Detector
Terminal
Strip
Cable
Shield
Red
White
Green
Black
LEL
Amplifier
W
PW R / SIG
SBR G
Calibration Cup/Splash G uard
Detector J-Box
Amplifier
J-Box
Red
White
Green
Black
Hydrogen
Detector