Manual

65-2434RK CO Transmitter 1
Overview
This manual describes the 65-2434RK carbon monoxide (CO) transmitter. This manual
also describes how to install, start up, maintain, and calibrate the transmitter. A parts list
at the end of this manual lists replacement parts and accessories for the CO transmitter.
Specifications
Table 1 lists specifications for the CO transmitter.
WARNING: When using the 65-2434RK, you must follow the instructions and warnings
in this manual to assure proper and safe operation of the 65-2434RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 65-2434RK as described in this manual.
Table 1: Specifications
Target Gas Carbon monoxide (CO)
Sampling Method Diffusion
Input Voltage 10 VDC - 30 VDC
Signal Output 4 - 20 mA
Detection Range 0 to 300 PPM (parts per million)
Accuracy ± 5% of reading or ± 5 ppm CO (whichever is greater)
Response Time 90% in 30 seconds