User Manual
2 • 35-3010RKA-06 Sample-Draw Detector
Description
This section describes the components of the 35-3010RKA-06 sample-draw detector. The
sample-draw detector consists of the housin g, fl ow system, and detection system.
Figure 1: Sample-Draw Detector Component Location
Housing
The sample -draw detecto r’s fiberglass housing is weather- and corrosion-resistant. It is
suitable for installation where g e neral purpose equipment is in use. The housing door is
hinged on the left side and is secured by two latches on the right side.
Four mounti ng feet are attached to the back of the housing (one at each corner). Use the
mounting feet to install the housing to a vertical surface. Use the two conduit hubs on the
bottom of the housing to make wiring connections.
+
24VBAT T
+
OXY
W
G
FB
4/20
TOXIC
TP +
ZE R O
OXY
TOXIC
TP -
BKRD
SPAN
Hydrophobic
Filter (AcroPak)
Flow
Blo ck
Amp 1
Pump
Preamp
Circuit
Board
H2S Sensor
Dummy Plug
LEL Transmitter
Charcoal Fi lter
Oxygen Sensor
CO Sensor
Combustible
Sensor
Amp 2
Inlet Fitting For 1/4" OD
Rigid Tubing
3/4 C onduit Hub, 2X
Exhaust Fitting For 1/4"
OD Ri gid Tu bing
Main Circuit Board
Oxygen Transmitter
Res et Switch