Specifications

10. CONNECTION TO ALLEN-BRADLEY PLC
10.2 Serial Connection
10 - 11
CONNECTION TO ALLEN-BRADLEY PLC
10
10.2.5 GOT Side Settings
Setting communication interface
(Communication settings)
Set the channel of the connected equipment.
1. Select [Common] [Controller Setting] from the
menu.
2. The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3. Set the following items.
Manufacturer: AB
Controller Type: Set either of the followings.
AB SLC500
AB MicroLogix
AB Control/CompactLogix
I/F: Interface to be used
Driver: Set either of the followings.
AB SLC500, AB 1:N
AB MicroLogix
AB Control/CompactLogix
4. The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
10.2.5 Communication detail settings
Click the [OK] button when settings are completed.
POINTPOINTPOINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
Communication detail settings
(1) AB SLC500, AB 1: Ns
*1 Do not specify the same value for the adapter address and
host address.
(2) AB MicroLogix
*1 Do not specify the same value for the adapter address and
host address.
2.
3.
4.
Click!
Item Description Range
Transmission
Speed
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
4800bps,
9600bps,
19200bps
Adapter Address
*1
Specify the adapter address (station
No. of the PLC that the GOT will
monitor) in the connected network.
(Default: 0)
0 to 31
Host Address
*1
Specify the host address (station No.
of the adapter to which the GOT is
connected) in the connected network.
(Default: 1)
1 to 31
Item Description Range
Transmission
Speed
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
4800bps,
9600bps,
19200bps,
38400bps
Sum Check Type
Specify the format in which the sum
check is performed during
communication when performing sum
check.
(Default: BCC)
BCC, CRC16
Adapter Address
*1
Specify the adapter address (station
No. of the PLC that the GOT will
monitor) in the connected network.
(Default: 0)
0 to 63
Host Address
*1
Specify the host address (station No.
of the adapter to which the GOT is
connected) in the connected network.
(Default: 1)
0 to 63