Specifications
9 - 52
9. CONNECTION TO RKC TEMPERATURE CONTROLLER
9.6 Device Range that Can Be Set
9.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may
not be monitored.
Setting item
*1 The following shows the relation between station numbers of the temperature controller and the GOT data register.
POINTPOINTPOINT
Device settings of RKC temperature controller
Item Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Information Displays the device type and setting range which are selected in [Device].
Network
Set the monitor target of the set device.
Station No.
To monitor the temperature controller of the specified station No.
1 to 99 :To monitor the temperature controller of the specified station No.
100 to 115 To specify the station No. of the temperature controller to be monitored by the value of GOT data
register (GD).
*1
Station No. GOT data register (GD) Setting range
100 GD10
1 to 99
(If setting a value outside
the range above, a device
range error occurs.)
101 GD11
::
114 GD24
115 GD25
Set by a value of "unit address + 1".
• For unit address 0: Set "1".
• For unit address F: Set "16".