Specifications

5 - 4
5. CONNECTION TO FUJI TEMPERATURE CONTROLLER
5.2 System Configuration
When connecting via RS-485 communication
*1 Including the cable length of the option devices.
*2 Product manufactured by MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED. For details of the product, contact
MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED.
5.2.2 Connecting to PXG4, PXG5, PXG9 or PXH9
When connecting to one temperature controller
*1 Product manufactured by FUJI CO., LTD. For details of the product, contact FUJI CO., LTD.
GOT
Connection cable
PXR3,PXR4,
PXR5,PXR9
PXR3,PXR4,
PXR5,PXR9
FUJI PXR/PXG/PXH
Communication driver
Temperature controller Connection cable GOT
Number of
connectable
equipment
Model
name
Communic
ation Type
Cable model
Connection diagram number
Max.
distance
Option device Model
PXR3
PXR4
PXR5
PXR9
RS-485
RS-485 connection diagram 4)
500m
*1
FA-LTBGT2R4CBL05(0.5m)
*2
FA-LTBGT2R4CBL10(1m)
*2
FA-LTBGT2R4CBL20(2m)
*2
Up to 31
temperature
controllers
for 1 GOT
RS-485 connection diagram 5)
500m GT15-RS4-TE
RS-485 connection diagram 7)
500m - (Built into GOT)
PXG4,PXG5,
PXG9,PXH9
GOT
Connection cable
FUJI PXR/PXG/PXH
Communication driver
Temperature controller Connection cable GOT
Number of connectable equipment
Model name
Communic
ation Type
Cable model
Connection diagram number
Max.
distance
Option device Model
PXG4
PXG5
PXG9
PXH9
RS-232
ZZPPXH1*TK4H4563
*1
3m
- (Built into GOT)
1 temperature controller for 1 GOT
GT15-RS2-9P