Instruction manual

3. MOUNTING
IMSRM52-E5
18
3.3 Mounting the Mother Block
The mother block can be mounted to a panel or on the DIN rail.
Mount the H-PCP module on the left side of the control unit.
Panel mounting directions
1. Refer to both the panel mounting dimensions below and the 3.2 Dimensions (P. 16) when
selecting the location.
4-M3
24
2-M3
24
77
24
24
77
77
H-LNK-A module H-PCP-G module Dimensions for multiple
module mounting
(Unit: mm)
2. Remove the module from the mother block. For details of removing the module, Refer to 3.5
Removing the Module Mainframe (P. 21).
3. Connect the mother blocks together before tightening the screws on the panel.
(Customer must provide the set screws)
Tightening torque
Recommended value: 0.3 Nm (3 kgfcm)
When the mother block is mounted on the panel,
50 mm or more space is required at the top and
bottom of the mother block to attach the module
mainframe.
M3 × 10
Mother block