Instruction manual

6. RKC COMMUNICATION
IMS01J02-E1
93
Continued from the previous page.
Name
Iden-
tifier
Digits
Attri-
bute
Struc-
ture
Data range
Factory
set
value
Display scale high
[H-TIO-H/J, H-CIO-A,
H-SIO-A]
XV
6 R/W C
Span 10000 or less
1
(Within 9999 to +10000)
H-TIO-H/J,
H-CIO-A:
100.0
H-SIO-A:
300
Display scale low
[H-TIO-H/J, H-CIO-A,
H-SIO-A]
XW
6 R/W C Span 10000 or less
1
(Within 9999 to +10000)
H-TIO-H/J,
H-CIO-A:
0.0
H-SIO-A:
0
Decimal point position
[H-TIO-H/J, H-CIO-A,
H-SIO-A]
XU
1 R/W C
0: No decimal place
1: One decimal place
2: Two decimal places
3: Three decimal places
H-TIO-H/J,
H-CIO-A:
1
H-SIO-A:
0
AO display scale high
[H-AO-A/B]
HV
6 R/W C Span 10000 or less
2
(Within 9999 to +10000)
100.0
AO display scale low
[H-AO-A/B]
HW
6 R/W C Span 10000 or less
2
(Within 9999 to +10000)
0.0
AO decimal point
position
[H-AO-A/B]
JR
1 R/W C
0: No decimal place
1: One decimal place
2: Two decimal places
3: Three decimal places
1
AO output change rate
limiter
[H-AO-A/B]
PW
6 R/W C 0.0 to 100.0 %/second
(0.0: OFF)
0.0
1
The position of the decimal point differs depending on Decimal point position (Identifier XU) setting.
2
The position of the decimal point differs depending on AO decimal point position (Identifier JR)
setting.
Continued on the next page.