Specifications
4. INPUT RANGE TABLES
IMR01H03-E4
56
Continued from the previous page.
Input type Input range Code
Input Range
0 to 800 °F
JA1
0 to 1600 °F
JA2
0 to 2192 °F
JA3
J
0 to 400 °F
JA6
−199.9 to +999.9 °F
1
JA9
0.0 to 800.0 °F
JB6
0 to 1600 °C
2
R01
0 to 1769 °C
2
R02
R
0 to 1350 °C
2
R04
0 to 3200 °F
2
RA1
0 to 3216 °F
2
RA2
0 to 1600 °C
2
S01
S
0 to 1769 °C
2
S02
0 to 3200 °F
2
SA1
0 to 3216 °F
2
SA2
400 to 1800 °C
B01
Thermocouple B
0 to 1820 °C
2
B02
800 to 3200 °F
BA1
0 to 3308 °F
2
BA2
0 to 800 °C
E01
E
0 to 1000 °C
E02
0 to 1600 °F
EA1
0 to 1832 °F
EA2
0 to 1200 °C
N01
N
0 to 1300 °C
N02
0.0 to 800.0 °C
N06
0 to 2300 °F
NA1
0 to 2372 °F
NA2
0.0 to 999.9 °F
NA5
−199.9 to +400.0 °C
1
T01
−199.9 to +100.0 °C
1
T02
−100.0 to +200.0 °C
T03
0.0 to 350.0 °C
T04
T
−199.9 to +752.0 °F
1
TA1
−100.0 to +200.0 °F
TA2
−100.0 to +400.0 °F
TA3
0.0 to 450.0 °F
TA4
0.0 to 752.0 °F
TA5
1
Accuracy is not guaranteed between −199.9 to −100.0 °C (−199.9 to −148.0 °F)
2
Accuracy is not guaranteed between 0 to 399 °C (0 to 751 °F)