Specifications

3. INITIALIZE COMMUNICATION DATA
IMR01H03-E4
54
Continued from the previous page.
Address CH Name
052CH (1324) CH1
052DH (1325) CH2
052EH (1326) CH3
052FH (1327) CH4 Alarm 3
0530H (1328)
CH5 differential gap setting
0531H (1329)
CH6
0532H (1330)
CH7
0533H (1331)
CH8
0534H (1332)
053BH (1339)
Unused
053CH (1340) OUT1
053DH (1341) OUT2 Control output logic
053EH (1342) OUT3 selection 1
053FH (1343) OUT4
0540H (1344) OUT5
0541H (1345) OUT6 Control output logic
0542H (1346) OUT7 selection 2
0543H (1347) OUT8
0544H (1348) ALM1 Alarm output logic
0545H (1349) ALM2 selection
0546H (1350) ALM3
0547H (1351)
054FH (1359)
Unused
0550H (1360) STOP display
selection
0551H (1361) Unused
0552H (1362) Contact input logic
selection
0553H (1363) Communication
protocol selection
0554H (1364) RUN/STOP transfer
logic selection