Instruction manual
3. DESCRIPTION OF EACH MODULES
IMSRM15-E6
70
3.9 H-DO Module
3.9.1 Outline
The H-DO module is used specially for digital output.
H-DO-A, H-DO-B and H-DO-D type modules can output alarm statuses* such as temperature and
heater break alarms independently for each channel.
* Alarm statuses of Temperature alarm 1, Temperature alarm 2, Burnout alarm, Heater break alarm, Loop
break alarm, AI alarm 1, and AI alarm 2.
For H-DO-C type modules, dedicated alarms or control unit operations can be independently output as
event outputs.
H-DO-A (8 points output type) H-DO-B (4 points output type)
DO1 to 4
(4 points/
common)
DO5 to 8
(4 points/
common)
DO1 to 8
(8 points/
common)
DO1 to 4
(All channel
independent
common)
Relay contact output type Open collector output type
Relay contact output type
H-DO-C (8 points output type) * H-DO-D (16 points output type)
Open collector output type Open collector output type
DO1 to 8
(8 points/common)
* H-DO-C module (event output function)
and the H-PCP module with the
specification of ladder communication
cannot be selected at the same time.
DO1 to 16
Vcc: 2 points (8 points/common)
GND: 2 points (8 points/common)