User`s manual

Entering Preset Setup
The MasterMind goes straight to Preset Setup when you enter Setup Mode. If you happen to be in Global Setup, you
can press the 1 / Function Select button to switch to Preset Setup. The red LED above the 1 / Function Select button
will light to tell you that Preset Setup is active. You are now ready to edit the rst parameter.
Watching the display, you’ll see that it alternates between displaying the current preset number, PC1 and a program
change number. If youre on preset 001 and haven’t changed anything from the defaults, you’ll see it alternate between
P001, PC1 and =001. This means that, for preset 001, it will send program change #1 to PC1. (Remember that PC1 is a
destination for Program Change messages and was set to a specic MIDI channel in Global Setup).
The LED above the 2 / Program/CC Number button will be lit, indicating that it can be used to change the program
number. Pressing this button will increment the program number by 1, until it reaches 128 (the maximum). Pressing it
again will set the program number back to the minimum, which is =001.
(Important Note: Some MIDI devices use program numbers 1 through 128 and some use program numbers 0 through
127. If your device is one of the latter, your program numbers will be o by 1. Selecting program 1 on the MasterMind
will cause the device to select program 0. Selecting program 2 on the MasterMind will cause the device to select
program 1, etc.)
All the other Preset parameters can be edited in this way. Pressing the 1 / Function Select button will move you to the
next parameter. If a parameter has been disabled in Global Setup (for example if PC2 is set to CH--), it will not appear in
Preset Setup. Once you reach the end of the parameter list, pressing 1 / Function Select again will bring you back to
the rst parameter in the list.
The Preset parameters are as follows:
PC1 - Program Change #1
(Program Change number range: =001 - =128 , Default value: preset 001 defaults to =001, preset 002 defaults to
=002, etc. )
Sets the program number for the rst Program Change destination. Press 2 / Program/CC Number to select the
program number.
PC2 - Program Change #2
(Program Change number range: =001 - =128 , Default value: 001)
Sets the program number for the second Program Change destination. Press 2 / Program/CC Number to select the
program number.
PC3 - Program Change #3
(Program Change number range: =001 - =128 , Default value: 001)
Sets the program number for the third Program Change destination. Press 2 / Program/CC Number to select the
program number.
PC4 - Program Change #4
(Program Change number range: =001 - =128, Default value: 001)
Sets the program number for the fourth Program Change destination. Press 2 / Program/CC Number to select the
program number.
14