Operator`s manual
Table Of Contents
- RS 8000/8600 Getting Started Guide
- Notices
- Table of Contents
- 1 About This Guide
- 2 Introduction
- 3 Hardware Installation
- 3.1 Safety Considerations
- 3.2 Hardware Specifications
- 3.3 Installing the Hardware
- 3.3.1 Verifying Your Shipment
- 3.3.2 Installing the Chassis
- 3.3.3 Installing an AC Power Supply
- 3.3.4 Installing a DC Power Supply
- 3.3.5 Installing the Control Module
- 3.3.6 Installing the Switching Fabric Module (RS8600 only)
- 3.3.7 Installing Line Cards
- 3.3.8 Installing GBIC Modules into Line Cards
- 3.3.9 Installing ATM Physical Media Cards (PHYs)
- 3.3.10 Multi-rate WAN Line Card and WICs
- 3.3.11 SRP Line Cards and Bridge Mate Module
- 3.3.12 Installing SFP Transceivers
- 3.3.13 Attaching the Network Cables to Line Cards
- 4 Initial Configuration
- 4.1 Powering on the RS8000/8600
- 4.2 Starting the Command Line Interface
- 4.3 Configuration Changes and Saving the Configuration File
- 4.4 Setting the Basic System Information
- 4.5 Setting Up Passwords
- 4.6 Setting Up SNMP
- 4.7 Setting the DNS Domain Name and Address
- 4.8 Setting the SYSLOG Parameters
- 4.9 Using Redundant Control Modules
- 5 Managing Software
- Appendix A Troubleshooting
- Appendix B International SaFety Information
- Index

Riverstone Networks RS 8000/8600 Switch Router Getting Started Guide 3-7
Hardware Installation Installing the Hardware
The following table lists the environmental specifications for the RS 8000/8600 DC power supplies.
RS 8600 DC Power Supply Wiring Options
Each RS 8600 DC power supply contains two internal supplies. Each of these internal power supplies must be
energized to produce sufficient power for the RS 8600 to operate. Figure 3-4 shows the internal relationship between
the screws on the wiring block and the internal supplies. Because of this internal arrangement, it is necessary to connect
both positive (+) screws and both negative (–) screws to the 48-Volt source. This section describes a few options for
connecting power to the RS 8600 power supply.
Figure 3-3 Front view of an RS 8600 DC power supply
Table 3-5 Environmental Specifications for DC Power Supply
Specification Measurement
Operating Temperature +5 to +40 °C (41 to 104 °F)
Non-operating temperature -30 to +73 °C (-22 to 164 °F)
Operating Humidity 15 to 90% (non-condensing)
PWR
G86-PDC
SN
48/60V
27A MAX
!
To be installed in a restricted
access area in accordance
with the NEC or authority
having jurisdiction.
See manual for installation
instructions.