Operator`s manual
Table Of Contents
- RS 8000/8600 Getting Started Guide
- Notices
- Table of Contents
- 1 About This Guide
- 2 Introduction
- 3 Hardware Installation
- 3.1 Safety Considerations
- 3.2 Hardware Specifications
- 3.3 Installing the Hardware
- 3.3.1 Verifying Your Shipment
- 3.3.2 Installing the Chassis
- 3.3.3 Installing an AC Power Supply
- 3.3.4 Installing a DC Power Supply
- 3.3.5 Installing the Control Module
- 3.3.6 Installing the Switching Fabric Module (RS8600 only)
- 3.3.7 Installing Line Cards
- 3.3.8 Installing GBIC Modules into Line Cards
- 3.3.9 Installing ATM Physical Media Cards (PHYs)
- 3.3.10 Multi-rate WAN Line Card and WICs
- 3.3.11 SRP Line Cards and Bridge Mate Module
- 3.3.12 Installing SFP Transceivers
- 3.3.13 Attaching the Network Cables to Line Cards
- 4 Initial Configuration
- 4.1 Powering on the RS8000/8600
- 4.2 Starting the Command Line Interface
- 4.3 Configuration Changes and Saving the Configuration File
- 4.4 Setting the Basic System Information
- 4.5 Setting Up Passwords
- 4.6 Setting Up SNMP
- 4.7 Setting the DNS Domain Name and Address
- 4.8 Setting the SYSLOG Parameters
- 4.9 Using Redundant Control Modules
- 5 Managing Software
- Appendix A Troubleshooting
- Appendix B International SaFety Information
- Index

2-14 Riverstone Networks RS 8000/8600 Switch Router Getting Started Guide
Hardware Overview Introduction
2.4.5 AC Power Supply
The power supply delivers 3.3, 5, and 12 DC volts to the RS’s Control Module(s), fan modules, and other components.
A single power supply provides enough current to operate a fully configured chassis. The power supply has its own
internal cooling fan. The vent on the front of the power supply is the inlet vent for the cooling fan.
Figure 2-4 shows the front view of an RS 8000 AC power supply.
Figure 2-4 Front view of an RS 8000 AC power supply
RXD (receive data) 3 TXD (transmit data)
Unused 4 Unused
Unused 5 Unused
RXD (receive data) 6 TXD (transmit data)
Unused 7 Unused
Unused 8 Unused
Table 2-5 Pin assignments for RJ-45 connector on Control Module
Control Module RJ-45
Connector
Pin Number Management Console RJ-45
Connector
G80-PAC
100-125~5A
200-240~3A
50-60 Hz
PWR