Instructions / Assembly

Page 15 of 17 20160615-Ver.1
TROUBLE SHOOTING
Problem:
Possible Causes:
Corrective Actions:
Burner will not
light
1. LP cylinder fuel is used up.
2. Burner may be obstructed.
3. Cylinder valve may be
closed.
4. Regulator is not properly
seated on cylinder valve.
1. Change a new full LP cylinder.
2. Refer to section of “Burner Cleaning”
at P.14 to clean the burner.
3. Check then open the cylinder valve.
4. Refer to section of Connecting
regulator to LP tank at P.6 to reinstall
regulator properly.
Fire at control
knob
1. Gas connections may be
loose.
2. Burner holes may be
obstructed.
1. Refer to the section of Leak Test at
P.11 to check and tighten all
connections.
2. Refer to section of “Burner Cleaning”
at P.14 to clean the burner.
Yellow flame at
burner
1. Burner is obstructed.
1. Refer to section of “Burner Cleaning”
at P.14 to clean the burner.
Flame blows
out on LOW
1. Burner holes may be
obstructed.
1. Refer to section of “Burner Cleaning”
at P.14 to clean the burner.
Burner does
not get hot
enough
1. Flow control device has been
activated in regulator.
1. Reset the regulator. Turn off the
burner and close the LP cylinder valve.
Disconnect the regulator from the LP
cylinder and wait for one minute.
Reconnect the regulator to the LP
cylinder and slowly open the LP
cylinder valve until the valve is fully
open. Light the burner and observe the
temperature.
Unit is too hot
1. Damaged or faulty regulator.
1. Replace the damaged parts with
factory authorized component.
Flare-up
1. Grease buildup.
1. Clean the burner.
Flashback
1. Burner is blocked.
1. Refer to section of “Burner Cleaning”
at P.14 to clean the burner.