User's Manual
Table Of Contents
- Table of Contents
- List of Figures
- Introduction
- Installing the Wireless Array
- Installation Prerequisites
- Planning Your Installation
- Installation Workflow
- Installing Your Wireless Array
- Powering Up the Wireless Array
- Establishing Communication with the Array
- Entering the License
- Performing the Express Setup Procedure
- The Web Management Interface
- Viewing Status on the Wireless Array
- Configuring the Wireless Array
- Express Setup
- Network
- Services
- VLANs
- Tunnels
- Security
- SSIDs
- Groups
- IAPs
- WDS
- Filters
- Clusters
- Using Tools on the Wireless Array
Wireless Array
Configuring the Wireless Array 315
If Timeshare mode is selected, you may adjust the following settings:
• Timeshare Scanning Interval (6-600): number of seconds between
monitor (off-channel) scans.
• Timeshare Station Threshold (0-240): when the number of stations
associated to the monitor radio exceeds this threshold, scanning is
halted.
• Timeshare Traffic Threshold (0-50000): when the number of packets
per second handled by the monitor radio exceeds this threshold,
scanning is halted.
RF Resilience
2. Radio Assurance Mode:
When this mode is enabled, the monitor radio
performs loopback tests on the Array. This mode requires RF Monitor
Mode to be enabled (Step 1) to enable self-monitoring functions. It also
requires a radio to be set to monitoring mode (see “Enabling Monitoring
on the Array” on page 460).
Operation of Radio Assurance mode is described in detail in “Array
Monitor and Radio Assurance Capabilities” on page 460.
The Radio Assurance mode scans and sends out probe requests on each
channel, in turn. It listens for all probe responses and beacons. These tests
are performed continuously (24/7). If no beacons or probe responses are
observed from a radio for a predetermined period, Radio Assurance
mode will take action according to the preference that you have specified:
• Failure alerts only — The Array will issue alerts in the Syslog, but
will not initiate repairs or reboots.
• Failure alerts & repairs, but no reboots — The Array will issue alerts
and perform resets of one or all of the radios if needed.
• Failure alerts & repairs & reboots if needed — The Array will issue
alerts, perform resets, and schedule reboots if needed.
• Disabled — Disable IAP radio assurance tests (no self-monitoring
occurs). Loopback tests are disabled by default.