User manual

8
B 3.3 Ending the function mode
If you do not want to carry out a function, exit the mode with ESC.
The mode is closed automatically after you have initiated the desired function i.e. after you have released the
corresponding action key.
All LED's stop flashing and the LED's standard display appears again.
C Installation
Switch off all connected servers.
Pull out the monitor, keyboard and mouse cables from the server.
Using a CPU connecting cable (Rittal no. 7551.1x0) make a connection between
keyboard, mouse and monitor interfaces of server 1 and the "Server 1" on the SSC mini4.
Connect further servers in the manner previously described.
Plug the keyboard and mouse into the corresponding socket on the SSC mini4. Afterwards connect the monitor
to the monitor interface on the rear of the equipment.
When all of the connections to the SSC mini4 have been made, switch on the server and the SSC mini4.
Switch on the server first, because otherwise the SSC mini4 will not be power supplied if no main power supply
is used.
Connect an additional main power supply + 5V, 300 mA (see technical data for exact specifications), if the
server's power supply is insufficient (switch malfunctions, no monitor display, no standard display on the LED's
etc.).
Monitor
Server 1Server 2Server 3
Server 4Mouse PS/2
Keyb. PS/2
+ 5V DC
min. 300mA
Server connection
with 7551.1x0 cable