Operating instructions
10 Technical specifications
Rittal fan-and-filter unit assembly and operating instructions 13
EN
Unit
Model No. SK
Fan-and-filter unit,
RAL 7035
–
3239.100 3239.110 3239.124
EMC fan-and-filter
unit,
RAL 7035
–
3239.600 – –
Rated operating
voltage
V
Hz
230, 1~,
50/60
115, 1~,
50/60
24 (DC)
Rated current max. A 0.12/0.11 0.24/0.23 0.28
Power
consumption
W 19/17 6
Pre-fuse T A 2
Dimensions
B1/H1 mm 204 x 204
B2/H2 mm 177 x 177
T1 mm 24
T2
(max. installation
depth)
mm 90
Air throughput,
unimpeded air flow
m³/h 105/120 105
Air throughput
with outlet filter
including standard
filter mat
m³/h
1 x 3239.200: 87/100
2 x 3239.200: 93/108
1 x 3240.200: 98/111
Outlet filter
–
3239.200
EMC outlet filter
–
3239.060
Fan – Diagonal, self-starting shaded pole motor Diagonal, DC motor
Noise pressure
level
dB (A) 46/49 46
Operating
temperature
°C –15 to +55
Storage
temperature
°C –30 to +70
Protection category
(to EN 60 529)
–
IP 54 standard
IP 55 with additional fine filter mat or hose-proof hood
IP 56 with hose-proof hood
Tab. 3: Technical specifications