Owner`s manual

For assistance, call RITRON at 800-872-1872, or go to www.ritron.com
8
QUICK TALK
TM
PROGRAMMABLE FEATURES.................................................................................................................................
QC or DQC Code
Select from a list of QC and DQC Codes to transmit subaudible
squelch tones for interference elimination.
DQC Invert
The DQC Digital Quiet Call
TM
code can be inverted for systems
that require inversion.
Compand
Set Compand for compression of the transmit audio.
“Companding” is a combination of audio “compression” in the
transmitter and audio “expanding” in the receiver. To determine
if your existing 2-way radios are using the Companding
feature, you can check the radio’s User Manual, contact your
radio dealer, or call Ritron for help.
TX Alert Tone
The RQT can transmit an alert tone before each voice
message transmission.
ANI
Power Alerts messages can be programmed with a unique 9
digit DTMF or 3-7 digit Selcall ANI string. The ANI will be
transmitted immediately prior to the Alert Tone and Power Alert
message. To program an ANI string, select Selcall or DTMF
and enter the string in the value field.
Message Repeat
Time between transmissions
This sets the amount of time the Quick Talk
TM
will wait before
re-transmitting a Power Alert message. For battery powered
operation this time will likely be 1 hour or more.
Repeat Message on each transmission
Your recorded voice message can be programmed to repeat
from one time to nine times on each Quick Talk
TM
radio
transmission, depending on how you program this feature.
Urgent messages may require more phrase repeats.
Voice Messages
Refer to the Recording Your Quick Talk
TM
Voice Messages
section of this manual for instructions on recording voice
messages.
Q
UICK TALK
TM
FACTORY DEFAULT PROGRAMMING ......................................................................................................................
TX Frequency (all inputs) 03 151.625 MHz (RQT-151)
02 154.570 MHz (RQT-151M)
26 467.850 MHz (RQT-451)
01 458.6625 MHz
(RQT-451-CANADA)
QC/DQC Code (all inputs) 44 No Tone
DQC Invert No
Compand No
Input Type Contact Closure
Analog Setpoints High 3.6 VDC
Low 1.7 VDC
Input Operation Normal
Latching Input Mode No
Dwell/Holdoff Time Open/High none
Closed/Low none
Number of Inputs Inputs 1 and 2
TX Alert Tone Yes
Power Strobe Time 250 mS
Append Power Messages Yes
Low Battery Message Yes
Power Fail Message No
Play Location Message No
Message Delay on TX 1 sec.
Recorded Messages
Input 1 Open/High “Switch 1 open”
Input 1 Closed/Low “Switch 1 closed”
Input 2 Open/High “Switch 2 open”
Input 2 Closed/Low “Switch 2 closed”
Power Fail “Quick Talk power fail”
Low Battery “Quick Talk battery”
Number of Times Recorded Message is repeated on each
Transmission
Inputs 1-4 Open/High One time
Inputs 1-4 Closed/Low One time
Power Alert One time
Number of Times the Transmission is sent
Inputs 1-4 Open/High No repeat
Inputs 1-4 Closed/Low No repeat
Power Fail Forever
Wait Time between Transmissions
Inputs 1-4 Open/High On change only
Inputs 1-4 Closed/Low On change only
Power Alert 1 Hour