Owner`s manual
6 Series OUTPOST
®
Wireless Callbox Field Programming
Have questions? Call 800-USA-1-USA (800-872-1872) or visit our website at www.ritron.com
T
ABLE
6:
A
DVANCED
F
EATURE
C
ODES
(
CONTINUED
)
........................
Code Feature Default Description
Switch Operation
811 No Switch * √ Disables 2-Tone decode and all switch operation.
812 Switch On When Called Switch closes (e.g. strobe light turns on) when Callbox 1
st
receives a
call. Switch opens (e.g. stobe light turns off) as soon as the PTT is
pressed. Enabling this feature will disable 2-Tone decode.
813 Switch On When Active Switch is closed (e.g. strobe light turns on) as long as Callbox is in use.
Switch opens (e.g. stobe light turns off) when Callbox has not been used
(transmit or receive) for a period of time longer than RQX Reset Time.
Enabling this feature will disable 2-Tone decode.
814 GateGuard
®
Momentary * Switch is closed for 1 second when correct 2-Tone Decode Code is
received. Enabling this feature will disable any previously programmed
2-Tone decode operation and require re-entry of the 2-Tone Decode
Code before it can operate.
815 GateGuard
®
Toggle Switch alternately closes and opens when correct 2-Tone Decode Code
is received. Enabling this feature will disable any previously
programmed 2-Tone decode operation and require re-entry of the 2-
Tone Decode Code before it can operate.
Special Features
821 Reset to Factory Defaults Resets Callbox to Factory default programming.
822 Display Radio Revision Callbox will display a sequence of 6 digits to identify operating code
revision. This is helpful when troubleshooting the radio.
823 Enable External +12 VDC Enables the External +12 VDC “Loss of power” notification feature.
824 Disable External +12 VDC √ Disables the External +12 VDC “Loss of power” notification and reverts
back to “Low Battery” notification.
825 Enable Auto Turn-Off √ Callbox will automatically turn off when it has not been used (transmit or
receive) for a period of time longer than the RQX Reset Time.
826 Disable Auto Turn-Off Callbox will remain on at all times. This mode of operation is not
recommended for battery-powered applications.
827 Enable Busy Channel TX Inhibit Callbox cannot transmit when there is a received signal. A “busy signal”
will be heard on the Callbox speaker when the PTT is pressed and a
received signal is present.
828 Disable Busy Channel TX Inhibit √ Callbox will transmit whenever the PTT is pressed, regardless of any
received signal.
829 Mic Gain High Places the microphone into high gain operation where quiet and distant
voices will be heard. This mode of operation will increase background
noise transmitted by the Callbox.
820 Mic Gain Normal √ Places the microphone into normal gain operation for the majority of
applications where the user is talking directly into the Callbox. This
mode of operation will decrease background noise transmitted by the
Callbox.
Listen In Time
870 Listen In Off √ The Callbox will automatically transmit for a period of time equal to the
871 Listen In 5 seconds Listen In Time when the correct 2-Tone decode code is received.
872 Listen In 10 seconds Programming Listen In Time will disable any previously programmed 2-
873 Listen In 20 seconds Tone decode operation and require re-entry of the 2-Tone Decode Code
874 Listen In 30 seconds before it can operate.
Receive Volume Level
875 10% Sets the speaker volume level of received signals.
876 25%
877 50% * √
878 75%
879 100% *
√ The Callbox is set from the factory with these options enabled.
* Setting is also available via Single-Digit Radio Feature Code programming.
16