User's Manual

________________________________________________________________________________________________________________________________
For assistance, call RITRON at 800-872-1872, or go to www.ritron.com
5
Setting the RQA-1B/4B .............................................................
1. Separate the case front and back by removing the four corner screws
and gently lift the case front. The case front and case back are
connected with a flex cable. Do not place strain on the flex cable when
separating the case.
2. Remove the battery.
3. Note the 3 programming options available, a 4-position CONFIG dip
switch, a 4-position LOCATION dip switch, and a 10-position ADDRESS
programming array.
4. Set the RQA-1B/4B per the following instructions.
5. Re-install the battery and verify operation with the RQT Quick Talk™.
Be sure to observe battery polarity when re-installing.
6. Carefully re-install the case front.
RQA-1B/4B SETTINGS
Setting the CONFIG Switches for Standard Operation
1. The single button RQA-1B can be set to send any 1 of 8 Message codes.
Set CONFIG switches 1 and 2
per the following chart to set the RQA-1B
Message code. These switches can be ignored on the RQA-4B.
2. Set CONFIG switch 3
for Group A messages (OFF) or Group B
messages (ON).
3. Set CONFIG switch 4
to the OFF position for Standard operation.
SW1
SW2 SW3 SW4
Message 1, Group A OFF OFF OFF OFF
Message 2, Group A ON OFF OFF OFF
Message 3, Group A OFF ON OFF OFF
Message 4, Group A ON ON OFF OFF
Message 1, Group B OFF OFF ON OFF
Message 2, Group B ON OFF ON OFF
Message 3, Group B OFF ON ON OFF
Message 4, Group B ON ON ON OFF
CONFIG Switch Settings for Standard operation
CARRY
OUT
PRICE
CHECK
OFFICE
SECURITY
RQA-4B
(Group A or B)
Message 1
Message 2
Message 3
Message 4
RQA-1B
(Group A or B)
Message
1, 2, 3, or 4