Owner`s manual

Page 20
Quick Talk Advanced Features/ Applications Manual
FREQUENCY PROGRAMMING
1-1 TX Freq. 2 digit code: Table 1 (See page 6.)
1-2 TX Freq., 6 digit: Dealer programming ONLY;
enter 1st 6 digits of frequency.
SUB-AUDIBLE CODED SQUELCH PROGRAMMING
2-1 CTCSS/ QC® 2-digit code: Table 2 (See page 7.)
2-2 DCS/ DQC
TM
3 digit code: Table 3 (See page 8.)
RECORDING VOICE PHRASES
3-1-1 Record “Switch 1 Open” Phrase
3-1-2 Record “Switch 1 Closed” Phrase
3-2-1 Record “Switch 2 Open” Phrase
3-2-2 Record “Switch 2 Closed” Phrase
3-3 Record Location Phrase
3-4 Record Power Failure Phrase
3-5 Record Low Battery Phrase
PLAY BACK PHRASES
4-1-1 Play Switch 1 OPEN Condition Phrase
4-1-2 Play Switch 1 CLOSED Condition Phrase
4-2-1 Play Switch 2 OPEN Condition Phrase
4-2-2 Play Switch 2 CLOSED Condition Phrase
4-3 Play Location Phrase
4-4 Play Power Fail Phrase
4-5 Play Low Battery Phrase
TIME BETWEEN MESSAGES:
SWITCH 1 OPEN
5-1-1-0 Suppressed messages
5-1-1-1 On changes only — DEFAULT
5-1-1-2 30 seconds
5-1-1-3 1 minute
5-1-1-4 2 minutes
5-1-1-5 5 minutes
5-1-1-6 10 minutes
5-1-1-7 30 minutes
5-1-1-8 1 hour
5-1-1-9 2 hours
SWITCH 1 CLOSED
5-1-2-0 Suppressed messages
5-1-2-1 On changes only — DEFAULT
5-1-2-2 30 seconds
5-1-2-3 1 minute
5-1-2-4 2 minutes
5-1-2-5 5 minutes
5-1-2-6 10 minutes
5-1-2-7 30 minutes
5-1-2-8 1 hour
5-1-2-9 2 hours
SWITCH 2 OPEN
5-2-1-0 Suppressed messages
5-2-1-1 On changes only — DEFAULT
5-2-1-2 30 seconds
5-2-1-3 1 minute
5-2-1-4 2 minutes
5-2-1-5 5 minutes
5-2-1-6 10 minutes
5-2-1-7 30 minutes
5-2-1-8 1 hour
5-2-1-9 2 hours
DIAL CODE DESCRIPTION
— QUICK REFERENCE GUIDE —
DIAL CODE DESCRIPTION
TIME BETWEEN MESSAGES:
(continued)
SWITCH 2 CLOSED
5-2-2-0 Suppressed messages
5-2-2-1 On changes only — DEFAULT
5-2-2-2 30 seconds
5-2-2-3 1 minute
5-2-2-4 2 minutes
5-2-2-5 5 minutes
5-2-2-6 10 minutes
5-2-2-7 30 minutes
5-2-2-8 1 hour
5-2-2-9 2 hours
SCHEDULED MESSAGE REPEAT LIMIT:
SWITCH 1 OPEN
6-1-1-1 One time
6-1-1-2 Two times
6-1-1-3 Three times
6-1-1-4 Four times
6-1-1-5 Five times
6-1-1-6 Six times
6-1-1-7 Seven times
6-1-1-8 Eight times
6-1-1-9 Repeat forever — DEFAULT
SWITCH 1 CLOSED
6-1-2-1 One time
6-1-2-2 Two times
6-1-2-3 Three times
6-1-2-4 Four times
6-1-2-5 Five times
6-1-2-6 Six times
6-1-2-7 Seven times
6-1-2-8 Eight times
6-1-2-9 Repeat forever — DEFAULT
SWITCH 2 OPEN
6-2-1-1 One time
6-2-1-2 Two times
6-2-1-3 Three times
6-2-1-4 Four times
6-2-1-5 Five times
6-2-1-6 Six times
6-2-1-7 Seven times
6-2-1-8 Eight times
6-2-1-9 Repeat forever — DEFAULT
SWITCH 2 CLOSED
6-2-2-1 One time
6-2-2-2 Two times
6-2-2-3 Three times
6-2-2-4 Four times
6-2-2-5 Five times
6-2-2-6 Six times
6-2-2-7 Seven times
6-2-2-8 Eight times
6-2-2-9 Repeat forever — DEFAULT
/
PHRASE REPEATS IN EACH MESSAGE:
SWITCH 1 OPEN
7-1-1-1 One time — DEFAULT
7-1-1-2 Two times
7-1-1-3 Three times
7-1-1-4 Four times
7-1-1-5 Five times
7-1-1-6 Six times
7-1-1-7 Seven times
7-1-1-8 Eight times
7-1-1-9 Nine times
{
NOTE: If Time
Between Messages
(above), is changed
from default On
Changes Only,
message is
repeated by active
Repeat Schedule.