Quick Start Manual
PG
18
PG
17
STEP 1 - Connect the G wire to
the G terminal on the thermostat.
This connects the Fan.
STEP 2 - Add a jumper wire
between W and Y.
STEP 3 - Connect the Y wire to
the Y terminal on the thermostat.
This connects the Compressor.
STEP 4 - Connect the O or B wire to the
O or B terminal on the thermostat. (If you have both O
and B wires, use the O and tape off the B).
This connects the change over valve.
STEP 5 - Connect the R wire to the RC terminal on
the Thermostat. This connects to the 24vac power.
STEP 6 - Connect W or W2 to W2 on the thermostat. This connects the AUX heat.
Your HVAC system is now connected to the thermostat.
Return To Page 9
HEAT PUMP
with Auxillary Heat
NOTE: Wires marked with the dotted line are optional.
STEP 1 - Connect the H wire to the H terminal on
the thermostat.
This connects the Humidifier.
STEP 2 - Connect the W wire to the W terminal on the
thermostat. This connects the Heat control line.
STEP 3 - Connect the R wire to the RH terminal on
the thermostat.
This connects the Heater Power.
Your Humidifier and heater are now connected to the thermostat.
Return To Page 9
NOTE: Wires marked with the dotted line are optional.
O or B
(not both)
HEAT PUMP
Change
Over
AUX
Heat
G
O or B
R
C
FAN
Y
Comp
24VAC
Power
jumper
wire
jumper
wire
Thermostat
Humidifier
H R W
C
24VAC
Power
jumper
wire
Thermostat
W
RH
H
Externa
l
H
um
idifier
w
/
any Heater
B
G
Y
R
C
Fro
m he
at p
ump
with
Aux he
at
O
or
W
or
W2