Specifications

Mounting Instructions
Determine an appropriate mounting location. The reader may be mounted to any surface, including metal.
Drill (2) 5/63-inch (2mm) holes approximately 1 inch deep for mounting the reader.
Drill a 5/8-inch (16mm) hole for the cable.
The reader may be mounted on a single gang back box.
Remove screw at bottom of reader and remove back cover from the reader and secure the reader to the mounting surface.
Route the cable from the reader and/or power supply to the host. A linear type power supply is recommended.
Check all electrical codes for proper cable installation.
Test the operation of the reader. After completion of the test, replace the back cover & screw.
Changes or modifications not expressly approved by the party responsible for compliance
could void the users authority to operate the equipment.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the
users authority to operate the equipment.
Kershaw Systems
Mfg. of RISG Products
USA / Southeast Asia
www.kershawsystems.com
949-335-5149
Testing Procedure
When Power is applied to the reader the LED will flash green while the beeper beeps Simultaneously. Then the LED will
turn red. This indicates the controller and the reader are operating properly
Present Prox Card to the reader. The LED will momentarily turn green while the beeper Beeps. This means the card was
read successfully.
Install & Test
Note: When mounting on metal surfaces read range could be affected. Placing a non metal gasket between the reader