Installation manual
Rinnai Australia 32 Installation Manual
HEATER INSTALLATION
Step 11. REPLACE PANELS
When satisfied that the appliance is igniting and operating correctly, replace lower horizontal cover
panel and the manual control switch panel in reverse order of ‘Step 3 (5)’ page 26.
Step 12. COMPLETE THE CLADDING
Fit the remainder of the cladding. For RDV3610ETR ensure non-combustible material is used in the
areas depicted in the drawings below.
RDV3610ETR
Non-combustible cladding dimensions
marked below are minimum size
requirements only, the non-combustible
cladding may extend beyond the
dimensions stipulated.
RDV3611ETR
Cladding MUST NOT extend lower than
the cladding support bracket.
WARNING
Top ledge of
the heater
cladding frame
Enclosure
framework
Non-combustible
Cladding
Non-combustible
Cladding
Non-combustible
Cladding
Non-combustible
Cladding
Front of
heater
400
150
1120
Non-combustible
Cladding
(shaded)
WARNING
Front of
heater
Enclosure
framework
Cladding
Cladding
Cladding
support
bracket
Cladding
support
bracket
Front of
heater
150
1120