Installation guide
4 | RDV3611 Installation Manual: 11156-A 01-12
Specication
310
1090
715
510
890
995
500
1060
400
149
750
775
845
All dimensions are in mm.
Cover panel
Covers 150 mm opening on both sides of the heater. Covers are removed only when a Symmetry Heat Transfer Kit is installed.
Outer frame
1110
643
538
1006ID
Specification summary
Input = 19-33 MJ/h
Output = 3.8-7.5 kW
Efficiency = 80%
Heating area = up to 100 m²
Gas type = NG or LPG
Symmetry RDV3611
A direct vent (natural draft) inbuilt
gas fireplace with a glass front and
convection fan (top discharge).
Operated with a remote control (7-
day programmable timer).
Combustion method
Ceramic top pan burner
Data plate
Centre front of base panel (behind the
service panels)
Flue
Inner: 100 mm, outer: 170 mm.
Appliance must be installed with a
Rinnai applied flue system.
Gas connection
½ “ BSP male flare
Ignition
Integrated sparker to pilot
Noise level
37-45 dB(A)
Power consumption
High = 50 W
Standby = <1 W
Standard electrical connection is to
the right side of the appliance.
Safety devices
Light to pilot, delayed ignition,
overheat switch, electronic flame
failure supervision, and combustion
chamber pressure relief.
Temperature control
Thermostatic, temperature control
range 7-32 °C.
Weight
60 kg