Installation manual

Rinnai Australia 20 Operation & Installation Manual
HOW TO OPERATE YOUR HEATER
The controller is factory set, therefore synchronise will not be necessary, however if you have
purchased the controller as a spare part then refer to the following.
Initial setup, synchronising the controller to your Symmetry heater, required only if the controller is
purchased as a spare or replacement part.
Before proceeding with synchronisation ensure that the gas and electricity are connected.
Two controllers CAN NOT be used at the same time!
Remote Controller - Synchronisation Step 1. Turn the power off at the power point for a minimum of 30
seconds, synchronisation will not be possible unless the
minimum 30 seconds has been observed.
Step 2. Ensure the remote control is turned off, to turn ‘OFF’ press
and release the ‘PWR’ button once.
Step 3. Turn the power on at the power point, the power operation
indicator on the control panel will flash once. The
controller can now be synchronised with the heater.
Synchronisation MUST BE performed within 30 seconds
of the power being turned on, if more than 30 seconds
has elapsed repeat steps 1 through 3.
Step 4. On the controller in quick succession press the following
sequence of buttons: ‘P’ >T’ > ‘T’ > ‘UP’.
The LCD display will show ‘L/C’ (Learn Code) for 2 seconds
then return to the normal ‘OFF’ state display.
The power operation indicator on the control panel will
flash once to indicate that synchronisation has been accepted.
To restore factory default settings With the thermostat ‘OFF’, press the following sequence of buttons ‘P’
> ‘T’ > ‘T’ > ‘DOWN’
Turning ‘ON’ and ‘OFF’ Turning ‘ON’
Press the ‘ON’/’OFF’ button, which is located on the ‘Manual Control
Switch Panel’ at the bottom right of the heater . The Power
Operation Indicator on the ‘Manual Control Switch Panel’ will turn
illuminate.
To transfer Operational control to the Remote Controller press both the
‘OK’ and ‘PWR’ buttons on the controller at the same time.
Turning ‘OFF’
To place the heater into controller standby press the ‘PWR’ button
once. The heater will go into ‘Standby’ mode and the Power Operation
Indicator on the ‘Manual Control Switch Panel’ will be extinguished.
To turn the heater ‘OFF’ press the ‘ON’/’OFF’ button twice. The
Power Operation Indicator on the ‘Manual Control Switch Panel’ will
remain extinguished to indicate that the appliance has returned to the
OFF condition.
Changing the temperature The Symmetry
®
has increments of 1° which can be changed using the
‘UP’ and ‘DOWN’ buttons.
The temperature control range is 7 - 32°C
Change between Celsius - °C and
Fahrenheit - °F
The thermostat temperature display can be set to °C or °F.
The default is °C.
With the thermostat ‘OFF’, press the following sequence of buttons:
‘P’ > ‘T’ > ‘T’ ‘A/M’ to toggle between °C or °F.
Change between manual, automatic and
flame modes
Press and release the A/M’ button.
NOTE
Square Fascia
11
12
4
9
Bevelled Fascia
11
10
4
9
9
4
NOTE
9
4
11
9
9
11
9