Installation manual

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E
05-10
26
Test pressures
1. Turn on the gas and power supply to the unit.
2. Refer to the data plate for applicable test point pressures.
3. The test point is on the gas control valve. Using a suitable screw driver loosen the
captivated test point screw and attach a manometer.
4. Using the manual control switch (on the appliance), turn the unit on and switch to the
HIGH setting and adjust the pressure as necessary.
5. Disconnect the solenoid (yellow wire). This will ensure the unit is on the lowest setting
and set the appliance to the LOW setting. Adjust the pressure as necessary. Reconnect the
solenoid.
Inlet test point
Outlet test point
Cap
Gas outlet
High pressure
adjusng screw
Low pressure
adjusng screw
6. After checking pressures, turn the unit off, remove manometer and replace test point
screw.
7. Turn the heater on and off a few times to check ignition.
8. When you are satised that the heater is working correctly, reassemble and start the
appliance to check the ame pattern (refer next page).
Adjust test point pressures as necessary
using a screwdriver and spanner as shown
below