Flue restrictor installation
The ue restrictor is required to be tted in installations where the ue length exceeds 2.3 m.
It works by limiting the amount of air required for combustion. The higher the ue the more
the air is circulated, this can affect the performance of the re.
Different ue congurations require a different positioning of the ue restrictor, please refer to
the Flue installation pages to determine what setting is required. The different hole positions
are shown below and also stamped on the restrictor.
Before you can install the ue restrictor you need to remove the pilot shield and carefully lift
the burner bed out of the unit. Attach the ue restrictor as shown by securing with the screws
provided.