Installation manual
Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E
05-10
15
Flue installation - Rinnai ue components
RDV3610 Flue Elbow 90°
Bend (R3643)
165
165
RDV3610 Flue Elbow 45°
Bend (R3642)
RDV3610 Flue Pipes
Used to facilitate vertical
and horizontal ueing. Elbow
swivels 360 ° at base. Angle not
adjustable.
Offsets obstructions as needed.
Elbow swivels 360 ° at base.
Angle not adjustable. Comes
packaged as a set of two.
Pipe used to construct horizontal
and vertical ueing (cannot be cut
to size).
108
108
Wall Terminal
(R3650)
Flue terminal required for
all horizontal installations
(aluminium).
Roof Cowl
(R3651)
Flue terminal required for all
vertical installations (aluminium).
Horizontal Flashing Kit
(R3646)
Wall Strap
(adjustable, R3647)
Used in interior/exterior
installations to add lateral
support to the ue. Provides
a 50-200 mm clearance to
combustible walls.
150 mm
(R3630)
230 mm (R3631)
300 mm (R3632)
450 mm (R3633)
600 mm (R3634)
900 mm (R3635)
1.2 m (R3636)
RDV3610 Flue Extension
75-175 mm (R3638)
75-360 mm (R3639)
Used for extending straight
lengths of ue. Available in two
lengths (extending to 175 or
360 mm)
Flue Elbow Strap
(R3644)
Used to prevent excessive
weight on the ue elbow.
Flue Restrictor
(supplied, 11516)
For vertical installations
greater than 2.3 m. Maintains
efciency by restricting air
ow through the unit as ue
length (ue pull) increases.
Flashing components used to
join internal ue to outside ue
terminal (to provide a weather-
tight seal) in horizontal ue
installations.
Bends - effective length
Once joined effective length
reduces 35 mm:
• 90° = 130 mm
• 45° = 73 mm
Flue Pipes - effective length
Once joined nominal length
reduces 35 mm:
Nominal Effective
• 150 mm = 117 mm
• 230 mm = 194 mm
• 300 mm = 270 mm
• 450 mm = 422 mm
• 600 mm = 575 mm
• 900 mm = 879 mm
• 1200 mm = 1184 mm
Effective lengths are variable
(from 35 mm) due to rounding of
the ue pipe dimensions.