Installation manual
Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E
05-10
14
Flue installation - Rinnai ue kits
Symmetry RDV3610 horizontal ue kits and dimensions
The following diagram explains the components, dimensions (mm) and appropriate ue kits
available for differing horizontal ue installations. Refer to the 'Distance from Appliance to the
Cowl' table to calculate what ue pipe length and/or kit you may need.
310
D
90� Elbow
Cowl
Flashing Kit
300 mm Pipe
Interior wall
600 mm Pipe
Base
1475
25
540
RDV3610 Short Horizontal Flue Kit A (R3660)
310
D
230 mm Pipe x 2
RDV3610 Long Horizontal Flue Kit B (R3661)
740
325-440
435-550
Distance from the appliance to the cowl
Horizontal Flue D
Kit A 300 mm Pipe 635 750
Kit B 230 mm Pipe x 2 745 860
300 mm + 230 mm Pipe 825 940
300 mm Pipe x 2 895 1010
• Adjust the distance by sliding the cowl on the pipe
• At its maximum position, the cowl should still keep a 45
mm overlap