Installation manual

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E
05-10
14
Flue installation - Rinnai ue kits
Symmetry RDV3610 horizontal ue kits and dimensions
The following diagram explains the components, dimensions (mm) and appropriate ue kits
available for differing horizontal ue installations. Refer to the 'Distance from Appliance to the
Cowl' table to calculate what ue pipe length and/or kit you may need.
310
D
90 Elbow
Cowl
Flashing Kit
300 mm Pipe
Interior wall
600 mm Pipe
Base
1475
25
540
RDV3610 Short Horizontal Flue Kit A (R3660)
310
D
230 mm Pipe x 2
RDV3610 Long Horizontal Flue Kit B (R3661)
740
325-440
435-550
Distance from the appliance to the cowl
Horizontal Flue D
Kit A 300 mm Pipe 635 750
Kit B 230 mm Pipe x 2 745 860
300 mm + 230 mm Pipe 825 940
300 mm Pipe x 2 895 1010
Adjust the distance by sliding the cowl on the pipe
At its maximum position, the cowl should still keep a 45
mm overlap