Flue Terminal Clearances
Ref
Description
Canadian Installations US Installations
A
Clearance above grade, veranda, porch, deck,
or balcony. (Take into account the anticipated
snow line)
6 inches (15 cm) for
appliances <
10,000 BTUh;
9 inches (23 cm) for
appliances > 10,000 BTUh
and <
50,000 BTUh,
12 inches (30 cm) for
appliances > 50,000 BTUh
6 inches (15 cm) for
appliances <
10,000 BTUh;
9 inches (23 cm) for
appliances > 10,000 BTUh
and <
50,000 BTUh,
12 inches (30 cm) for
appliances > 50,000 BTUh
B
Clearance to window or door that may be
opened
12 inches (30 cm) 9 inches (23 cm)
C Clearance to permanently closed window * *
D
Vertical clearance to ventilated soffit, located
above the terminal within a horizontal distance of
2 feet (61 cm) from the center line of the terminal
* *
E Clearance to unventilated soffit * *
F Clearance to outside corner * *
G Clearance to inside corner 20 inches (50 cm) 20 inches (50 cm)
H
Clearance to each side of center line extended
above meter/regulator assembly
3 feet (91 cm) within a
height 15 feet (4.5 m) above
the meter/regulator
assembly
*
I Clearance to service regulator vent outlet 3 feet (91 cm) *
J
Clearance to nonmechanical air supply inlet to
building or the combustion air inlet to any other
appliance
12 inches (30 cm) 9 inches (23 cm)
K
Clearance to a mechanical air supply inlet
6 feet (1.83 m)
3 feet (91 cm) above if
within 10 feet (3 m)
horizontally
L
Clearance above paved sidewalk or paved
driveway located on public property
7 feet (2.13 m) 1 *
M
Clearance under veranda, porch, deck, or
balcony
12 inches (30 cm) to non-
flammables 2
24 inches (60 cm) to
flammables 2
12 inches (30 cm) to non-
flammables 2
24 inches (60 cm) to
flammables 2
1 A vent shall not
terminate directly above
a sidewalk or paved
driveway that is located
between two single
family dwellings and
serves both dwellings.
2 Permitted only if
veranda, porch, deck,
or balcony is fully open
on a minimum of two
sides beneath the floor.
For clearances not
specified in ANSI
Z223.1/NFPA 54 or
CSA B149.1,
clearances are in
accordance with local
installation codes and
the requirements of the
gas supplier.