Installation Manual

23
HE Series Infrared Gas Heater Installation and Operation Manual
: (Horizontal vent through side wall is on pages 20 -
21)
It is the sole responsibility of the installer to adhere to all current local codes and/or ANSI
Z223.1 latest editions for all venting requirements, and practices.
Refer to General Venting Requirements on page 19


Any horizontal portion of vent must be mini-
mum 26 gauge single wall type Cvent
pipe of 4” (10 cm) diameter (seal all con-
nections); vertical portion of vent can be 4”
type Bvent
When the vent pipe passes through a cold
or unheated area where the ambient tem-
perature is likely to result in condensation
of the flue gases, the vent pipe will be
type B vent or insulated with a suitable
material as approved and specified by the
insulation manufacturer to withstand tem-
perature up to 460°F (238°C).
Use an approved B-venttermination cap
as supplied by the manufacturer of the
listed B-vent’.
Minimum length of a vertical roof vent:
Minimum 12 inch length (1 ft; 30 cm)
single wall Cvent
Plus one 90° Cvent elbow
Plus minimum 36 inch (3 ft; 92 cm)
double wall Bvent
Total minimum linear vent length of 48
inches (4 ft; 122 cm) plus one 9C
elbow
Maximum length of a vertical roof vent:
Above minimum requirements must be met
A maximum of one 90° elbow (equivalent 5 ft) plus two 45° elbows (each equivalent to
2.5 ft) can be installed in a vertical vent system
Refer to local and national codes for maximum allowable venting
Approved
Cap
Approved
BVent
24”
60 cm
12
9
If roof slope exceeds 9:12
consult NFPA-54 ANSI
Z223.1

Up
to
Minimum 12(30 cm)
Length CVent
Minimum 36” (92 cm)
BVent
90° CVent
Elbow
Cto BAdapter
Thimble
