HE Series Infrared Gas Heater Installation and Operation Manual
Use all four suspension points plus a chain at the burner eye hook.
Hardware capable of supporting minimum 100 lb (45 kg) at
each suspension point.
For seismic and high wind restraint see
Sections 10-A & 10-B.
: ALLOW A MINIMUM
OF 6 INCHES (15 cm) FROM THE ACCESS
END OF THE BURNER AND A MINIMUM
OF 24 INCHES (60 cm) FROM EITHER
SIDE OF THE BURNER TO A WALL OR
ANY OBSTRUCTION THAT WOULD RE-
STRICT OR LIMIT ACCESS TO THE BURN-
ER (SEE SECTIONS 6 & 7 - PRE-
INSTALLATION SURVEY AND MOUNTING
CLEARANCES)
Connect to properly
grounded 120V
power supply
Inadequate or improper suspension of the tube heater can result in collapse of
the system, property damage, and personal injury or death. Suspend the heat-
er from a structural member that can adequately support the weight of the
heater. Always maintain the required minimum clearances to combustible ma-
terials and vehicles (see pages 7 to 10).
It is the installer’s responsibility to ensure that the hardware and structural sup-
ports from which the heater is suspended are sound and of adequate strength to support the
weight [86 lb (39 kg)] and expansion forces of the heater.
-
5.
KEEP THE HEATER HORIZONTAL / LEVEL ALONG
ITS LENGTH WHILE HANDLING AND INSTALLING
6. LIFT SAFELY - LIFT WITH YOUR LEGS AND
KEEP BACK STRAIGHT - DO NOT BEND
OR TWIST.
7. BEWARE - SHARP EDGES!
WEAR PROTECTIVE GLOVES AND
CLOTHING WHEN HANDLING