User manual
42
TECHNICAL DETAILS 
* Minimum operation flow based on temperature setpoint and inlet conditions. 
Infinity Model 
Infinity 16i 
Units
Installation Internal    
G20 Nat Gas Press Low  1.8  mbar 
G20 Nat Gas Press High  9.0  mbar   
G25 Nat Gas Press Low  1.8  mbar 
G25 Nat Gas Press High  9.0  mbar   
G30 LPG (Butane) Press Low  2.2  mbar 
G30 LPG (Butane) Press High  11.4  mbar   
G31 LPG (Propane) Press Low  2.2  mbar   
G31 LPG Propane) Press High  14.2  mbar   
Height 675 mm  
Width 370 mm  
Depth 130 mm  
Weight 15 kg 
Flue System  Concentric Forced Draught 
Temp. Range Controllers  35 - 60  deg C 
Max Temp. via dip switch  75  deg C   
Ignition  Direct Electronic Ignition 
Gas Consumption Low (Gross)     
G20 Nat Gas  4.7  kW 
0.4
G25 Nat Gas  4.0  kW  0.4 
G30 LPG (Butane)  4.9  kW  .35 
G31 LPG (Propane)  4.9  kW  .35 
Gas Consumption High (Gross)       
G20 Nat Gas  34.9  kW  3.26 
G25 Nat Gas  29.6  kW  3.26 
G30 LPG (Butane)  36.8  kW  2.6 
G31 LPG (Propane)  36.5  kW  2.6 
Max Flow raised 25C  15.2  L/min 
Min Operation Flow  2.4*  L/min   
Water Pressure Nom.  1.1 - 7.0  bar 
Power Supply 
Electric Consumption  68  Watts 
230 V / 50 Hz 
m
3
/hr 
m
3
/hr 
kg/hr 
kg/hr 
m
3
/hr 
m
3
/hr 
kg/hr 
kg/hr 