Installation and User Manual REU - 16 FUA - E “Infinity 16 i” Continuous Flow Water Heater Important. Read these instructions carefully before attempting installation or use of this appliance. All work must be carried out by competent persons.
CONTENTS Contents………………………………………………………………..…………………3 User Instructions.....................................................................................................4 Features and Benefits………………………………………………..………….5 Important Information…………………………………………...……..………..6 Operation without Remotes……………………………………………….……8 Temperature Controls…………………………………………….……………..9 Caring for the Infinity..................................................................................
USERS INSTRUCTIONS The following instructions are designed for the user of the water heater. The user may not install or adjust the appliance in any way that requires the removal of the front of the unit. To remove the front cover of the unit you must be certified competent to do so. Information for the Installer is given on page 22. All work done on this appliance must be done by a qualified gas engineer.
FEATURES AND BENEFITS Congratulations on purchasing the Technologically Advanced, Temperature Controlled, Rinnai Hot Water System. x The Rinnai Infinity 16i will NEVER RUN OUT of hot water. As long as electricity, water, and gas supplies are connected, hot water is available when hot water taps are open. x Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the hot water supplied. The water temperature may be set to various temperatures.
IMPORTANT INFORMATION Excessively hot water is dangerous, especially for young children and the infirm. The water heater allows you to control the temperature of your hot water to safe levels. Water temperature over 50ºC can cause severe burns instantly or even death from scalding. Children, disabled and the elderly are at the highest risk of being scalded by excessively hot water. Always test the temperature of the water before bathing or showering.
IMPORTANT INFORMATION Always check water temperature before use. Hot water may go cold without warning at very low water flows (less than 3 l/min.) OFF Refer to warning about hot water on page 16 for important safety information. The Infinity 16i controls the water temperature automatically. For high temperatures it may reduce the flow. The water from the hot tap may be reduced after the temperature shown on the remote control is raised.
TEMPERATURE CONTROLS The purpose of a Temperature Controller is to enable the user to have complete control over the hot water supply. Used correctly, the Infinity will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjustments to the operation of your hot water unit can be made with any of the Temperature Controllers. Each Temperature Controller can be individually programmed.
TEMPERATURE CONTROLS - OPERATING Remote temperature controllers are a feature that provides control over the water temperature. The Rinnai Infinity 16i water heater can be operated with 1, 2, or 3 temperature controllers. The controller MC-45-SR-EU comes as standard with this water heater installed into the front panel. Digital Monitor Priority Indicator Priority Button Indicates the temperature selected. Error message flashes in the event of a fault.
TEMPERATURE CONTROLS - OPERATING Using the Temperature Controllers. Press the ON/OFF button on a temperature controller. The system will become active, the temperature will default to 400C and the controller that turned the system on will have priority. The temperature setting on the controller will light up. Adjusting Temperature Simply press the Hot Water Temperature Up or Down arrow button until the desired temperature is displayed on the digital display.
TEMPERATURE CONTROLS - OPERATING Using 2 or more Temperature Controllers. Switching the system ON. The hot water system and all controllers can be switched ON and OFF from any controller by pressing the ON/OFF button as shown. When the system is turned ON the water temperature display will be lit. . During normal operation the system is left ON. Do not push the ON/OFF button when water is running. Ensure the system is switched On by verifying the temperature display is lit.
TEMPERATURE CONTROLS - INFORMATION Do not push the ON/OFF button on the Master controller after transferring priority of temperature selection to a Secondary controller as the system will shut down. Temperature priority can not be switched to another controller when the water is flowing through the water heater.
CARING FOR THE INFINITY Maintenance Even if there does not seem to be a problem with the water heater it is required in the UK that all gas appliances are serviced every year by a certified gas engineer. This is to ensure continued safety of the gas appliance. If you need a recommended service engineer contact Rinnai or your supplier. Care When the appliance casing, operation panel, and remote controls surfaces become dirty gently wipe them clean with a soft, damp cloth.
ERROR MESSAGES Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will flash on the Digital Display if you have temperature controllers installed. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. Some of these remedies can not be checked by the user because they require the front to be taken off of the unit.
ERROR MESSAGES Troubleshooting without controllers If you have not installed temperature controllers and experience the following symptoms, please carry out the suggestions below. If symptoms continue, please contact Rinnai for advice. Fault Remedy Heater does not attempt Check the power is on at the heater. to start at all. Check the cold water valve supplying the heater is open. Heater starts then shuts down immediately. Check the power is on.
RESTARTING THE RINNAI WATER HEATER Following a power cut the heaters should be restarted in this manner. Standard system. Single or multiple water heaters without remote controllers. The heaters will automatically reset without any user involvement. Single or multiple water heaters with remote controllers. The heaters will be required to be switched on using the ON/OFF button on a remote controller. Ensure that all taps/water outlets are closed and no water is flowing through heaters.
INSTALLATION INSTRUCTIONS STOP To go beyond this point in the manual you must be a registered gas engineer. Do not attempt to install this appliance if you are not qualified. If the information in this manual is not followed exactly a fire or explosion could result. This manual must be read in its entirety before installing the appliance. If you are unsure of any point contact Rinnai or your supplier.
UK INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION This appliance may only be installed by someone certified competent to do so. At the time of printing the only people deemed competent to install this appliance are those that are CORGI registered for this type of appliance in this type of location who have a current ACS certificate. 1. Gas safety (Installation & Use) regulations 1998 are the ‘Rules in force’.
OPERATION PRINCIPLE HOT WATER SUPPLY OPERATION Ignition Press ON/OFF Button of Remote Controller to turn on unit and the remote controller display and priority LED will light up. When a hot water tap is opened the Water Flow Sensor revolves and sends a pulse signal to the Printed Circuit Board (PCB.) When the PCB detects water flow it begins the ignition process with the Combustion Fan Motor starting first.
MAIN COMPONENTS 1. Gas Control Unit 1.1 Modulating Valve This device is used by the PCB to adjust the volume of gas to the burner in proportion to the volumetric flow rate of water in order to maintain a supply of constant temperature hot water amid changes in water flow rates and incoming temperatures. 1.2 Change-over Solenoid Valves Additional solenoid valves are included to section the burner and stage the control in 3 steps.
MAIN COMPONENTS 3. Thermal Fuse The thermal fuse is an electric link which must be intact for the unit to operate. If the thermal fuse reaches a set temperature it will melt and the unit will shut down. The thermal fuse must be replaced if it melts. It is to protect against over heating and heat exchanger splits where water may leak out and be super heated into steam. 4. Overheat Safety (Bi-metal Switch) This Bi-metal Switch is fixed at the bend of the Heat Exchanger hot water outlet.
INSTALLATION INSTRUCTIONS - POSITIONING Appliance Location. The wall or structure on which it is mounted must be capable of supporting the weight of the appliance (15 kg) and associated pipework. Ensure that suitable screws or bolts are used to secure the water heater to the wall. Bracket and fixing hole locations are shown on the template included. The top bracket has a keyhole slot so that the appliance can be hung on one screw, and then the other fixings can be added to secure the unit.
INSTALLATION INSTRUCTIONS - CONNECTIONS Water Supply. Where the water supply pressure exceeds 7 bar, an approved pressure reducing device is required at the inlet of the appliance. To achieve the maximum rated flow a minimum water supply pressure of 1.1 bar is required at the appliance inlet. The unit will operate at lower supply pressures but the maximum flow rate will not be achieved. Contact Rinnai or your supplier for 'gravity fed' or 'low pressure' hot water installations.
UK INST. INSTRUCTIONS - CONNECTIONS Water Connection. For all closed systems (with flow and return or tank) the system must incorporate an unvented kit with the components shown below. The safety relieve valve must discharge safely into a suitable drain via tundish.
INSTALLATION INSTRUCTIONS - SCHEMATICS Single Infinity Direct Flow Direct feed to the hot water outlets. Mains is fed directly into the unit. Standard domestic or small commercial set up. Used with controllers to alter the temperature at the point of use (only using hot tap) or temperature set on the dip switches for the maximum needed at any outlet, and mixed down by TMVs or manual tempering valves.
UK INST. INSTRUCTIONS - VENTILATION General Information. This appliance must be installed in accordance with the rules in force. Consult instructions before installations and use of this appliance. The unit must be installed by a competent, authorised person. It is the installer’s responsibility to ensure that the unit has been installed to all current requirements. The Rinnai Infinity 16i is a room sealed appliance.
FLUE REQUIREMENTS - INSTALLING The flue must be installed by a competent, authorised person. It is the installer’s responsibility to ensure that the unit has been installed to all current local requirements. Ensure that the flue terminal and hot water outlet connection cannot be touched by children. The flue must be clear of obstructions and shrubbery. Flue Length. The flue Total Equivalent Length is limited to 6.5m. Each 900 bend should be considered 0.5m of the Total Equivalent Length.
FLUE REQUIREMENTS - INSTALLING The following flue manufacturers with their specific brands listed below are approved for use with the Rinnai Infinity 16i water heater. 1. UBBINK The following combinations of flue materials may be used with the Rinnai water heater Rolux® flue system Roof terminal black T200 L =1000 mm Wall terminal T200 Alu 800mm black Wall terminal T200 Alu 800mm white 2.
UK FLUE REQUIREMENTS - INSTALLING The Rinnai Infinity 16i is for internal installation in conjunction with the Rinnai flue system The flue must be installed in accordance with: Manufacturers Installation Instructions British Standards including BS5440 Gas Safety (Installation and Use) Regulations IGE/UP/10 Part1 Edition 2. Building Regulation J Such other specifications and regulations that may supersede or complement the above documents. The flue must be installed by a competent, authorised person.
UK FLUE REQUIREMENTS - POSITIONING Dimension Terminal Position Distance A Directly below an opening, air brick, opening windows, etc. 300mm B Above an opening, air brick , opening window, etc. 300mm C Horizontally to an opening, air brick , opening window, etc. 300mm D Below gutters, soil pipes or drain pipes. 75mm E Below eaves. 200mm F Below balconies or car port roof. 200mm G From a vertical drain pipe or soil pipe. 150mm H From an internal or external corner.
TEMPERATURE CONTROLS - INSTALLATION When deciding on the best position for the temperature controls, the following points should be taken into account. x Fit the controls out of reach of children (suggested height from the floor 1.5m.) x Avoid positions where the controllers will become hot. Do not fit them near stoves or ovens, or above radiators or heaters. x If possible, avoid exposure to direct sunlight or positions where bright lights will make the digital display difficult to read.
GAS PRESSURE SETTING The working gas pressure on the water heater is electronically controlled and factory set. Under normal circumstances it does not require adjustment during installation. Perform this procedure only if the unit is not operating correctly and all other possible causes for incorrect operation have been eliminated. Contact Rinnai before attempting to alter the gas pressure. Failure to do so could void the warranty. 1. Turn 'OFF' the gas supply. 2. Turn 'OFF' 230V power supply. 3.
DIP SWITCH SETTING Dip Switch Positions Explained OFF ON SW 1 2 3 4 5 6 7 8 - Gas Type Gas Type Computer Programming Computer Programming Computer Programming Max. Temperature Combustion Combustion LEGEND: Black Section indicates position of dip switch.
DIMENSIONS 41
TECHNICAL DETAILS Infinity Model Installation Units Infinity 16i Internal G20 Nat Gas Press Low 1.8 mbar G20 Nat Gas Press High 9.0 mbar G25 Nat Gas Press Low 1.8 mbar G25 Nat Gas Press High 9.0 mbar G30 LPG (Butane) Press Low 2.2 mbar G30 LPG (Butane) Press High 11.4 mbar G31 LPG (Propane) Press Low 2.2 mbar G31 LPG Propane) Press High 14.2 mbar Height 675 mm Width 370 mm Depth 130 mm Weight 15 kg Flue System Concentric Forced Draught Temp.
FLOW CHART 43
WIRING DIAGRAM 44
DIAGNOSTIC POINTS Flow Chart No. Ԙ Measurement point CN Wire Color Component GEARED MORTOR Ԛ REMOTE CON TROLS WATER FLOW SENSOR Remark I B-Br A1 R-B DC11㨪13V 10㨪30ǡ Drive power R-Bk Y-Bk AC power Control power Full open limiter ON2.4L/min (35Hz) over 2100 pulse/min. OFF1.
LETTER OF COMPLIANCE 46
CE CERTIFICATE 47
COMMISSIONING CHECK LIST COLD HOT GAS 48
UK WARRANTY As the purchaser of this high quality Rinnai Water Heater you are provided with the following conditional warranty. Standard Use Heat Exchanger All Other Parts Parts Labour Parts Labour 1 Year 1 Year Year 1 Year 1 Year 1 Year 1 Year 1 Year 16i Commercial Use 16i Rinnai Infinity units used in Commercial Situations are only subject to a 1 year warranty across the board. Commercial situations should be supplied by the Rinnai HD range.
SPECIFICATION Model………………………………………………..…....…………......................Infinity 16i Installation…………………………………………...………...……... Internal location only Fuel…………………………………………………..….…………..…...Natural Gas or LPG * Control………………………………………………….……………...…….….…..Modulating Output (nominal)………………..………………………...…..……….………4 kW to 30 kW Exhaust type…………………………………………...…………….....Forced Draught Flue Ignition………………………………………………...…………….………………..Electronic Burner……………………………………………………...…………………....