Models: ORH15SR ORH18MR ORH24LR ORH32XLR Outdoor Radiant Heater Operation & Installation Manual
This appliance must be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000 • Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person� For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions� Rinnai 2 ORH OIM
TABLE OF CONTENTS Warnings and Important Information 4 About Your Outdoor Radiant Heater 7 Radiant Heating Principles ��������������������������������������������������������������������������������������������������������������������������������� 7 Features ������������������������������������������������������������������������������������������������������������������������������������������������������������� 7 Specifications ���������������������������������������������������������������������
WARNINGS AND IMPORTANT INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. IMPORTANT Always comply with the following precautions to avoid dangerous situations and to ensure optimum performance. Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in personal injury or death.
WARNINGS AND IMPORTANT INFORMATION WARNING The electrical cord MUST NOT come into contact with the heated parts of the appliance. DO NOT unplug the appliance by pulling on the flexible cord. DO NOT coil or bundle the electric cord to reduce its length as overheating of the cord may occur which could result in a fire hazard. Use of an extension cord on this appliance is not recommended. The appliance is NOT intended to be used as a portable heater.
IMPORTANT MANDATORY INSPECTION PRIOR TO INSTALLATION Immediately report any damage or discrepancies to your appliance supplier. This appliance has been inspected and tested at the time of manufacture and packaging, and was released for transportation without known damage. Upon receipt, inspect the exterior for evidence of rough handling in shipment. Ensure that the appliance is labelled correctly for the gas and electrical supply it is intended to be connected to.
ABOUT YOUR OUTDOOR RADIANT HEATER RADIANT HEATING PRINCIPLES Radiant heat is widely regarded as the most comfortable, healthiest and most natural form of outdoor heating available. This heating type is based on the same primary source of heat we know - the warmth of the sun. It warms you and the objects around you instead of the air. The warmth felt from the sun is not warm air but infra-red energy.
ABOUT YOUR OUTDOOR RADIANT HEATER GENERAL DESIGN LAYOUT / CARTON CONTENTS Models: ORH1 5R ORH1 8MR ORH2 4LR ORH3 2XLR 6 4 Outdo Opera or Rad tion & iant He Installa ater tion Ma nual 5 1a 7 5 4 1b 2 3 The packaging for this appliance should contain: 1. Outdoor Radiant Heater: a. Heater body b. Front radiating surface. 2. 1000mm Flexible power cord with three pin plug (fitted) 3. Operation Indicator Light 4. Adjustable angle mounting bracket fittings (x2) 5.
INSTALLATION 3. The red operation indicator will flash to indicate the heater is in Standby mode. 4. Point the remote control towards the indicator light area of the heater to operate it. Press “On” button on the remote control to turn on the heater and the heater will begin to radiate infrared heat. The red operation indicator will light and a beep will be heard. NOTE The heater may take up to 15 minutes to reach maximum heat, depending on the area being heated and the conditions. 5.
INSTALLATION REGULATORY REQUIREMENTS • • • The heater must be installed in accordance with the manufacturers installation instructions. The heater MUST ONLY be installed or removed by an authorised person. The heater MUST be installed in accordance with AS/NZS 3000 and all other applicable local municipal building codes including OH&S requirements UNPACKING IMPORTANT If any damage is present DO NOT INSTALL or OPERATE the appliance and contact your supplier for advice.
INSTALLATION CLEARANCES Minimum clearances when mounting the heater on A VERTICAL WALL. Fans, lights and sprinkler fittings MUST NOT be below heater 220 Min. 1500 Min. 100 Min. 1000 Min. to surfaces (ie table tops, ect) 2100 Min. from floor 3000 Max. from floor (recommended) 600 Min. Same both ends 600 Min. Same both ends Minimum clearances when mounting the heater parallel with A CEILING. 175 Min 600 Min Fans, lights and sprinkler fittings MUST NOT be below heater 600 Min 1000 Min.
INSTALLATION INSTALLATION METHOD 1. Open the packaging and carefully take the heater out and inspect for any damage. 2. Determine the mounting position for the heater, refer to "Approximate Heating Area" on page 10 "Outdoor Radiant Heater Mounting" on page 10 and 11 to assist with the location of the heater. 3. Set the adjustable angle mounting brackets to desired angle: For ceiling mounted installations the available mount angles are restricted to 0°, 15° and 30° only.
CARE & MAINTENANCE ELECTRICAL CONNECTIONS WARNING The installation of electrical wiring, power outlets, and switches MUST BE performed by an authorised electrical installer. GPO Connection The heater is provided with a power cord fitted with a 3 pin plug (models ORH15SR, ORH18MR and ORH24LR are fitted with a 10 Amp plug and model ORH32XLR is fitted with a 15 Amp plug) for connection to a dedicated single-phase 240V AC~ 50HZ earthed power outlet.
CLEANING ALWAYS TURN OFF AND OR ISOLATE THE POWER BEFORE CLEANING. WARNING CAUTION NEVER IMMERSE THE APPLIANCE IN WATER. Before operating the heater for the first time or after extended periods of non use ensure that the surfaces are clean and free of debris or dust. Once the radiating surface are clean avoid touching to prevent any transfer of skin oils to the heating surfaces as this may cause spotting or staining. NEVER ATTEMPT TO CLEAN THE HEATER WHILE HOT, ALWAYS WAIT FOR IT TO COOL DOWN.
WARRANTY Rinnai Outdoor Radiant Heater Product Warranty NOTICE TO CONSUMERS UNDER AUSTRALIAN CONSUMER LAW Notice to consumers under the Australian Consumer Law: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
WARRANTY 4. WHAT WE NEED YOU TO DO We need you to assist us with your claim by: 5.
WARRANTY 6. EXCLUSIONS No warranties except those implied and that by law cannot be excluded are given by Rinnai in respect of Goods supplied. Where it is lawful to do so, the liability of Rinnai for a breach of a condition or warranty is limited to the repair or replacement of the Goods, the supply of equivalent Goods, the payment of the cost of repairing or replacing the Goods or acquiring equivalent Goods as determined by Rinnai.
NOTES Rinnai 18 ORH OIM
NOTES Rinnai 19 ORH OIM
CONTACTS Rinnai Australia Pty Ltd ABN 74 005 138 769 | AU24752 100 Atlantic Drive, Keysborough, Victoria 3173 P.O. Box 460, Braeside, Victoria 3195 Tel: (03) 9271 6625 Fax: (03) 9271 6622 National Help Line Tel: 1300 555 545* Fax: 1300 555 655 Monday to Friday, 8.00 am to 5.00 pm EST. *Cost of a local call higher from mobile or public phones. For further information visit www.rinnai.com.au or email enquiry@rinnai.com.