SPECIFICATION
Model………………………………………………..…....……….....Infinity 26e and HD50e
Installation…………………………………………...………...……. External location only
Fuel…………………………………………………..….……………... Natural Gas or LPG *
Control………………………………………………….……………...……….…..Modulating
Input……………………………………………………..……….……………......4.4 to 55 kW
Exhaust type…………………………………………...……………....Forced Draught Flue
Ignition………………………………………………...…………….…………...…..Electronic
Burner……………………………………………………...…………………...Stainless steel
Weight…………………………………………………...……….……………..…..………21kg
Water flow rate ………………………………………..……………….…...2.4 ** to 32L/min
Minimum operating water pressure…………………..……….…………..……….1.0 Bar
Connections
Gas…………………………………………………………...….………………….…….3/4BSP
Water Inlet………………………………………….………...…………………….……3/4BSP
Water outlet…………………………………….………...………………………….…..3/4BSP
Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph
*Separate models available for Natural gas or LPG fuel.
** Minimum flow rate based on Temperature Setpoint and Inlet conditions.
Rinnai are continually updating and improving products and reserve the right to
alter model specifications without prior notice.