User manual

25
TEMPERATURE CONTROLS - INFORMATION
Do not push the On/Off button on the
Master controller after transferring priority
of temperature selection to a Secondary
controller as the system will shut down.
Do Not
Turn OFF
the Master
Controller
Temperature priority can not be switched
to another controller when the water is
flowing through the water heater.
Do not clean the remote control with
solvents or detergents. Use only a soft
damp cloth.
50
°
C
Controller 1
in use
Controller 2
cannot take
priority
Depending on the weather conditions
and the length of the pipe between the
heater and the tap in use, there may be a
variation between the temperature dis-
played at the controller and the tempera-
ture at the tap.
48
°
C
If a temperature higher than 50°C has
been selected on the Master controller
and priority of temperature selection is
transferred to another controller (or 
controller is turned OFF), then back again
(or turned ON again), the temperature on
the Master controller will automatically
drop to 50°C. If the set point is less than
50°C it will not alter. This is a safety feature.
If a temperature higher than 42°C has
been selected on the Universal controller
and priority of temperature selection is
transferred to another controller (or 
controller is turned OFF), then back again
(or turned ON again), the temperature will 
automatically drop to 42°C. If the set point 
is less than 42°C it will not alter. This is a 
safety feature.
Master
Controller
Another
Controller
(or turned OFF)
Master
Controller
(or turned ON again)
Universal
Controller
Another
Controller
(or turned OFF)
Universal
Controller
(or turned ON again)