Installation and Operation Guide

Model
Infinity
16
Infinity
20
Infinity
26
Infinity
26i
Infinity
26
Smartstart
Infinity
26 Touch
Enviro
26
Infinity
32
Enviro
32
Flow rate l/min @ 25° rise 16 20 26 26 26 26 26 32 32
Min operating flow rate 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
Installation External External External Internal External External External External External
Gas consumption MJ/h (high) 125 160 199 195 199 199 172 250 211
Star Rating 6.2 6.1 6.1 6.1 6.1 6.1 7.0 (Eq) 5.9 7.0 (Eq)
Pre Set Temps 50°/60° 50°/60° 50°/60° 50°/60° 50° 50º/60ºC 60° 50°/60° 60°
Domestic use Warranty
Parts and labour
“3 years (extends to 5 with the addition of 2 or more temperature controllers)”
Heat exchanger (part only) 12 years 12 years 12 years 12 years 12 years 12 years 12 years 12 years 12 years
Gas Type NG / LP NG / LP NG / LP NG / LP NG / LP NG / LP NG / LP NG / LP NG / LP
Weight (kg) 15 15 16 21 26 16 29 29 32
Max water supply pressure
(kPa)
1000 1000 1000 1000 500 1000 1000 1000 1000
Min water supply pressure
(kPa)
120 160 200 140 200 200 250 180 250
Cold Water connection
(mm)
15 (1/2”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”)
Hot Water connection (mm) 15 (1/2”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”)
Gas Connection (mm) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”) 20 (3/4”)
Condensate drain \ return
line (mm)
N/A N/A N/A N/A 20 (3/4”) N/A 15 (1/2”) N/A 15 (1/2”)
Status monitor Y Y Y Y N Y Y Y Y