REU-V1616W/REU-V2018W/REU-V2020W - 29 - Issue 1 - 10/10/03 ©Rinnai
13. Hot Water Outlet Thermistor Circuit
Check Hot Water Thermistor if error code “32” is displayed.
Disconnect relay connector (B
1
) and measure resistance White -White.
When disconnected: resistance >1M
When short circuit: resistance > 1
Normal: Check Heat exchanger outlet thermistor
Faulty: Replace hot water outlet thermistor.
If normal proceed to Flame Rod circuit.
Faulty: Replace the Hot water Outlet Thermistor.
Note: For controller readout of thermistor temperature whilst operational refer maintenance monitor.
Disconnect relay connector (B
1
) and measure resistance White -White.
14. Surge Protector
Check the fuse.
a.) Unplug the power plug.
b.) Check whether or not the fuse (3A) x 2 has blown by measuring the resistance.
Normal: <1
If normal go to step Electrical Fuse 13.
Faulty: Replace fuse/s (3Ax2). Check for a short next time it’s turned off.
15. Electrical Fuse
a.) Measure voltage between Blue and Brown on the connector (F
2
)
Normal :AC 207~264V
If normal proceed to b.). (11~13Ω)
Faulty: Check if voltage on the fuse terminal is AC207~264V
b.) Measure voltage between white and white on the (F
1
).
Normal: AC207~264V.
Faulty: replace surge protector unit.
16. Transformer
Check for the transformer
a.) Measure the voltage between white and white on the transmission connector (F).
Normal: AC207~264V (11~13 )
If normal proceed to b.). (11~13)
Faulty: Check if the voltage on fuse terminals is AC207-264V.
Normal
Temp.
15
o
C30
o
C45
o
C60
o
C
Resistance 11.4∼14 k 6.4~7.8 k 3.6~4.5 k 2.2~2.7 k
Service Manual Infinity 16e and 20e
Service Manual Infinity 16e and 20e