Specifications

www.foreverhotwater.com www.comfortableheatingsolutions.com © 2007 Rinnai Corporation
www.rinnai.us © 2010 Rinnai Corporation
15
All ES, EX, and C-Series models will attempt restart after a power failure or flame failure to
ensure heating is not interrupted for extended periods of time
If there is a power failure while the appliance is operating, the unit will attempt to restart
automatically when the power is restored
The timers will retain their settings after a power outage
After an outage, the clock will retain the time at that moment until power resumes. Therefore, a short
power outage (a few minutes) will have virtually no effect on timer operations whereas a longer outage
will require the clock to be reset. Dashes will initially display to indicate an outage occurred.
Should a high gust of wind, gas outage, etc. occur that affects the flame characteristic, the
unit will automatically shut down, purge the combustion chamber, and re-ignite
If the unit cannot ignite or maintain flame for 15 seconds after ignition, code 11 will flash
and the unit will try to ignite again in one hour
This code will not be stored in the fault code history
If at some point after 15 seconds of established flame the flame fails, the unit will
immediately attempt to relight with no code flashing
If the unit cannot relight after this flame failure, code 11 will flash and the unit will try to ignite again
in one hour
If the unit continually or intermittently fails to ignite, a qualified service technician may be needed to
determine the cause
Each manual has a section named ―Restart Function‖ that explains this procedure
Flame failure fault codes (code 12’s) are no longer needed due to this enhancement
Restart Features