Specifications
www.foreverhotwater.com • www.comfortableheatingsolutions.com • © 2007 Rinnai Corporation
www.rinnai.us • © 2010 Rinnai Corporation
15
All ES, EX, and C-Series models will attempt restart after a power failure or flame failure to
ensure heating is not interrupted for extended periods of time
• If there is a power failure while the appliance is operating, the unit will attempt to restart
automatically when the power is restored
• The timers will retain their settings after a power outage
• After an outage, the clock will retain the time at that moment until power resumes. Therefore, a short
power outage (a few minutes) will have virtually no effect on timer operations whereas a longer outage
will require the clock to be reset. Dashes will initially display to indicate an outage occurred.
• Should a high gust of wind, gas outage, etc. occur that affects the flame characteristic, the
unit will automatically shut down, purge the combustion chamber, and re-ignite
• If the unit cannot ignite or maintain flame for 15 seconds after ignition, code 11 will flash
and the unit will try to ignite again in one hour
• This code will not be stored in the fault code history
• If at some point after 15 seconds of established flame the flame fails, the unit will
immediately attempt to relight with no code flashing
• If the unit cannot relight after this flame failure, code 11 will flash and the unit will try to ignite again
in one hour
• If the unit continually or intermittently fails to ignite, a qualified service technician may be needed to
determine the cause
• Each manual has a section named ―Restart Function‖ that explains this procedure
• Flame failure fault codes (code 12’s) are no longer needed due to this enhancement
Restart Features