Specifications
12
Overview of installer parameters and adjustment options
HYDRAULIC Level
The parameters of this level refer to the general hydraulic system of the boiler as
well as to the functionality and conguration of the programmable inputs and outputs for
the corresponding boiler components.
Parameter Designation Setting range / Setting values
Fact.
setting
Individual
setting
02
Function assignment of output
for DHW-loading pump
OFF No function
1 DHW-loading pump
1
05
Function assignment of output
for unmixed circuit pump
OFF No function
2 Unmixed circuit pump
6 Constant control unit
2
SYSTEM Level
The parameters in this level refer to the general limiting parameters and setting values in
the heating system to be used.
Parameter
Designation Setting range / Setting values
Fact.
setting
Individual
setting
LANGUAGE
Font language
selection
DE German CZ Czech
GB English PL Polish
FR French RO Romanian
IT Italian RU Russian
NL Dutch TR Turkish
ES Spanish S Swedish
PT Portuguese N Norwegian
HU Hungarian
D
TIME
PROGRAM
Number of enabled time
programs
P1 Only one time program enabled
(unmarked)
P1-P3 Three time programs enabled,
(marked)
P1
CONTROL
MODE
Enabling of separate control
mode setting
1 Common adjustment for all
Heating circuits
2 Separate adjustment for every
individual heating circuit
1
SUMMER
Limit temperature for summer
switch o
OFF no function
System frost protection…86°F (30 °C)
20 °C
05
System frost protection
OFF no function
-4°F (-20°C)...Summer switch-o
3 °C
09
Climate zone -4°F..32°F (-20..0.0°C)
-12 °C
10
Type of building
1 light construction
2 medium construction
3 heavy construction
2
11
Time for automatic exit
OFF No automatic return
0,5...5 after adaptation time, autom.
(min) return to standard display
2 min
13
Logical error message OFF, ON OFF
18
Release cycle temperature OFF, ON ON
19
Frost protection mode
OFF Permafrost protection according to Adj.
Param. 5
0,5...60 min cyclic operation
OFF
23
Anti-blocking protection OFF (0000), 0001...9999 OFF
68 °F
37 °F
10 °F