Specifications
Installation & Servicing Instructions E-Range
33
15 Technical specifications
Technical specifications Table 9
Boiler type E32S
Input Hs CH kW 32
Q
n
Output Hi CH
kW 28.8
Efficiency class according BED
Efficiency according EN677
(36/30°C part load. Hi)
% 109.9
Efficiency according EN677
(80/60°C full load. Hi)
% 97.9
Modulation range CH
(capacity 80/60°C)
kW 6.1 - 28.2
Modulation range CH
(capacity 50/30°C)
kW 6.8 - 30.6
Nox class EN483 5
CO
2
%9
Temperature class for PP flue T100
Appliance type C13 C43 C53 C63 C83
Flue gas temp. CH
(80/60°C on full load)
°C 68
Flue gas temp. CH
(50/30°C on low load)
°C 31
Categories II2L3P
Gas consumption G20 CH (DHW)
(at 1013 mbar/15°C)
m
3
/h
3.05
Electr. power consumption max. W 145
Electr. power consumption stand by W 10
Current V/Hz 230/50
Fuse rating A 5
Degree of protection acc. EN 60529 IPX4D
Weight (empty) kg 40
Width mm 500
Height mm 870
Depth mm 395
Water content CH l 5
After run time pump CH min 19
After run time pump DHW min
P
MS
Water pressure min./max.
bar 1/3
Flow temperature max. °C 85
Pump type UP20-60
Available pump height CH kPa 17
CE product identification number(PIN) 0063BR3409