Installation Manual
Demand Duo™ R-Series Installation and Operation Manual 30
3. Remove the desired knockout along the
perimeter of the electric box for conduit
installation (Figure 25).
2. Remove the two screws around the outlet
cover. Remove the outlet cover and
prewired outlet (Figure 24).
Figure 23
Figure 24
Figure 25
4. Install conduit into the knockout opening
and pull the green, white and black wires
into the box.
5. Strip the green, white, and black field sup-
plied wires 1/2 in. Make sure the conductors
are completely bare (Figure 26).
Figure 26
6. Match the wire colors, then grip the wire
firmly and push the conductor into open
port of the push in connector (Figure 27).
Figure 27
1. Locate the electric conduit on the side of
the water heater (Figure 23).
Use only one conductor per port. Verify
conductor is fully inserted to the back of
the connector.
NOTE