Installation Manual

Demand DuoH-Series Installation and Operation Manual 43
1. Install a manual gas control valve in the gas
supply line to the water heater. A union can
be used on the connection above the shut off
valve for the future servicing or disconnection
of the water heater (Figure 45 on the follow-
ing page).
2. Check the type of gas and gas supply pres-
sure before connecting the water heater. If
the water heater is not of the gas type that
the building is supplied with, DO NOT con-
nect the water heater. Contact the dealer for
the proper water heater to match the gas
type.
3. Check the gas supply pressure immediately
upstream at a location provided by the gas
company. Supplied gas pressure must be
within the limits shown in the Section “3.2
Specificationswith all gas appliances oper-
ating.
A licensed professional must install the gas
supply.
Turn off 120V power supply.
Turn off the gas.
Gas is flammable. Do not smoke or provide
other ignition sources while working with
gas.
Do not turn on the water heater or gas until
all fumes are gone.
WARNING
To connect the gas supply, follow the instructions
below:
3/4 in. MNPT Gas Connection
on Bottom of Water Heater
Topics in this section
Connect the Gas Supply
Connect Electricity
Pump Controller
Figure 45
Figure 46
The gas swivel and gas
flex line can move in
multiple directions for
installation.